Tank Check UK off-mains drainage

Guide

Septic tank vs sewage treatment plant vs cesspit

What is the difference between a septic tank, a sewage treatment plant and a cesspit?

Quick answer

A septic tank settles solids and sends liquid to a drainage field in the ground. A sewage treatment plant treats the sewage more thoroughly, often with mechanical parts, and may be allowed to discharge to a watercourse if it meets the rules. A cesspit (cesspool) is a sealed tank with no outlet, so everything stays in the tank until a tanker empties it. In England, a septic tank must not discharge to a ditch or stream.

Last updated 18 November 2026 (Europe/London).

Septic tank

A septic tank is a settlement tank. Solids collect at the bottom as sludge, and a liquid effluent leaves the tank to soak into the ground through a drainage field. The Environment Agency’s guidance on discharges to the ground is written around this arrangement. Official English guidance is that you must not discharge effluent from a septic tank to a watercourse. The tank still needs regular desludging by a registered waste carrier, at least once a year or in line with the manufacturer’s instructions.

Sewage treatment plant

A packaged sewage treatment plant treats the sewage more thoroughly than a septic tank, usually with mechanical or air-assisted parts. Because the effluent is treated to a higher standard, the Environment Agency’s surface-water general binding rules allow a small sewage treatment plant (and not a septic tank) to discharge to a watercourse, if the other rules are met. Those rules include volume limits, maintenance, and not causing pollution.

Treatment plants need servicing as well as desludging. Follow the manufacturer’s schedule and keep records. British Water publishes technical guides, including Flows and Loads, used by installers when a system is being sized, and maintains a list of accredited service engineers — see British Water publications.

Cesspit or cesspool

GOV.UK uses the word cesspool for a sealed tank with no outlet. Nothing is discharged to the ground or to a stream, so the general binding rules for small sewage discharges do not apply in the same way. Everything that goes in stays in until a tanker empties it, which is why a cesspool generally needs emptying more often than a septic tank serving the same household. See how often to empty and typical emptying costs.

When English rules require you to change system

If you have a septic tank in England that discharges to a surface water, the Environment Agency says you must replace it or change how it discharges. The options given in the surface-water general binding rules are:

  • connect to a mains sewer where it is reasonable to do so;
  • install a drainage field so the septic tank discharges to ground instead, if the ground rules can be met;
  • replace the septic tank with a small sewage treatment plant that meets the rules for a discharge to surface water.

You usually have to send the Environment Agency plans within 12 months. An older 1 January 2020 deadline that people still mention was withdrawn; the current wording is about sending plans and then completing the work in a reasonable timescale. The rules in Scotland, Wales and Northern Ireland are different: read SEPA, Natural Resources Wales and DAERA. This is not legal advice.